Abstract:How do I do if my hand dryer is broken? Now many places will use the hand dryer, the hand dryer does bring a lot of convenience to people, the hand dryer will also have a failure of the time, such as, the hand dryer indicator light does not light, also does not work; no hot air blowing out, only cold air blowing out; indicator light is on, but the induction sensitivity is low, etc.. So, how to repair the hand dryer is broken? This article is a simple introduction for everyone!

 

Common faults with jet hand dryers


Fault phenomenon 1: hand into the hot air outlet, no hot air blowing out, only cold air blowing out.


Analysis and maintenance: there is cold air blowing out, that the blower motor is powered to work, infrared detection and control circuit is normal. Only cold air, that
The heater is broken or wired loosely. Upon inspection, the heater wiring is loose. After reconnection, there is hot air blowing out, the fault is removed.

 

Fault phenomenon 2: after the power, the hand has not been placed on the hot air outlet. Hot air that is out of control blowing out.


Analysis and maintenance: after checking, silicon controlled no breakdown phenomenon, suspected of photocoupler ③, ④ feet of internal leakage of phototransistor breakdown. After replacing the photocoupler, the work returned to normal, the fault is eliminated.

 

Fault phenomenon 3: hand into the hot air outlet, no hot air blowing out.


Analysis and maintenance: check the fan and the heater is normal, measuring the silicon gate without trigger voltage, measuring the control triode VI of the c pole rectangular wave signal output, suspected that the photocoupler is bad e, with a multimeter RxI0 block measurement photocoupler ③, ④ feet between the positive and reverse resistance are infinity, the normal forward resistance value should be a number of m, reverse resistance value is infinity, determined to be the internal photosensitive tube open circuit, resulting in the silicon gate can not get trigger voltage and can not conduct. After replacing the photocoupler, the fault is removed.

 

Fault phenomenon 4: power on the light is on, but no hot air blowing out after reaching.


Analysis of the fan and the heater at the same time the possibility of failure is very small, mostly seen as a bad relay or not action, and J not action may be V3 not conductive; op amp no output. D6, D5 failure; V1, V2 did not start or 7812 damage caused by no 12V voltage. Check first to measure the presence of 12V, if there is, reach out and test the op-amp (7) pin level has not changed. If there is a change, check V3 and relay backwards; if there is no change, check forward op-amp circuit, photoelectric conversion and oscillation circuit.

 

Fault phenomenon 5: power on the indicator light, but the induction sensitivity is low.


This fault in addition to the op amp circuit has anomalies, mostly seen for the red launch and receive tube is dust pollution, cleaning can be.
 

Relevant News

Commercial stainless Steel hand dryer fast dry 8-10s

Install interhasa hand dryers and say no to the spread of germsWhy do we always emphasize the importance of personal hygiene? Whenever we enter a crowded public plac...

Automatic liquid touchless sensor soap dispenser for bathroom

Automatic soap dispenser makes hygiene simple and fastWhen we are in hospitals or in film and television works, we can always notice that doctors wear a variety of p...

Wall Mounted Folding Baby Changing Table For Baby

Why it is recommended that you use a baby care table when caring for your babyOur lives have changed dramatically since our baby was born. The addition of new member...

Your Quality
Hand Dryer Manufacturer

And our knowledge in manufacturing and R&D ensures all of our products surpass your expectations in terms of service life and performance.

Good Quality

The quality, safety and
reliable supplier recognized by
many customers!

Fast Delivery

We promise to
deliver within 1-15 days

Rich Products

We offer more than
500 different models in 15
categories

Full After Sales Service

Professional customer
service team provides 24/7
customer service

GET A QUOTE

Get in Touch

×