News

Induction sensor faucet failure repair methods

Publish Time: Author: Site Editor Visit: 697

As a sensor faucet manufacturer, for the usual sensor faucet common failures also have a certain understanding, next to give you an analysis of how to solve the problem of sensor faucet failure it
Induction faucet common fault repair methods
A, induction faucet not ice
1, the water valve off: if someone turned off the valve, then certainly not out of the water. There are reasons why the valve is a problem.
2, filter blockage: some faucets in order to prevent the sand into the filter, unscrew the faucet interface to see if there is anything blocking the filter.
3, the water pressure is too small: If you live on a high floor, you may encounter a lack of water pressure, resulting in water can not play up, the water is very little condition.
4, faucet problems: check - the other places with water is normal, if normal, then certainly the faucet problems.
5, blocked water pipe: If the water pipe is blocked, this will require professional staff to deal with.
6, there is no water in the tank: due to water outages or water overuse, resulting in no water storage tank, of course, there will be no water.
Second, the induction faucet a water
1. No induction (indicator did not light) often flowing water
First of all, exclude the induction window in front of the foreign body, and the indicator is normal, check the water control part of the water inlet filter whether there is sediment or other debris blockage, such as please clean clean. If you can not solve the problem, please disassemble the solenoid valve, clean the coil spool, spring, diaphragm, etc. and then installed back in the same way, such as still can not close the water means that the solenoid valve is bad, replace the new solenoid valve part can. Note that in the maintenance process to close the water valve, to avoid wasting more water.

 


2, there is induction (indicator light) often flowing water
First check whether there are impurities blocking the water inlet, if not, after induction by hand, carefully listen to the solenoid valve spool whether to work (with the sound of opening and closing, if there is work, then disassemble the faucet solenoid valve internal cleaning, and then installed back as is.
Third, the induction faucet water output is small
On the one hand to see whether the water pressure and pipeline flow is small, in addition - check the water control part of the inlet end of the filter whether there are impurities blocked, but also on the one hand to consider the current PPR pipes are used, part of the project construction pipe joints using hot fusion, do not rule out excessive hot fusion will deform the pipe, so that the water through the pipe is quite small. If you will not Then find the bathroom maintenance master help.
Fourth, induction faucet dripping water leakage
Prepare the cross screwdriver, a screwdriver, active wrench, etc., filter cleaning needs solenoid valve with a front filter can be used, cleaning impurities are divided into cleaning filter impurities and cleaning the solenoid valve coil head impurities. Network impurities and cleaning the solenoid valve coil head impurities in two cases, before cleaning impurities, please adjust the water adjustment valve to the closed state, or close the main water valve switch. Then use "a" screwdriver to spin out the filter, rinse clean with water and reassemble the screw and open the water adjustment valve. Special attention, before taking down the filter must first close the water regulating Valve. Induction faucet flow requirements are 0.05 ~ 0.125L / s, if the induction faucet encounter flow is getting smaller and smaller can not close the water, consider cleaning the solenoid valve filter.
Five, induction faucet can not close tight
1, the principle of the sensor is as long as there are objects in the infrared induction distance range, the machine will respond, so you can exclude whether there is a foreign body in front of the induction window, can exclude the problem of the indicator, should be normal.
2, first check the water control part of the water inlet filter whether there is mud, sand, or other debris blockage, if any, immediately clean, and then regularly check.
3, you can also try to disassemble the solenoid valve, clean the coil spool, spring, diaphragm, re-installed; if the water is still not controlled, the solenoid valve has been damaged up, need to replace a new one.


 

Relevant News

Commercial stainless Steel hand dryer fast dry 8-10s

Install interhasa hand dryers and say no to the spread of germsWhy do we always emphasize the importance of personal hygiene? Whenever we enter a crowded public plac...

Automatic liquid touchless sensor soap dispenser for bathroom

Automatic soap dispenser makes hygiene simple and fastWhen we are in hospitals or in film and television works, we can always notice that doctors wear a variety of p...

Wall Mounted Folding Baby Changing Table For Baby

Why it is recommended that you use a baby care table when caring for your babyOur lives have changed dramatically since our baby was born. The addition of new member...

Your Quality
Hand Dryer Manufacturer

And our knowledge in manufacturing and R&D ensures all of our products surpass your expectations in terms of service life and performance.

Good Quality

The quality, safety and
reliable supplier recognized by
many customers!

Fast Delivery

We promise to
deliver within 1-15 days

Rich Products

We offer more than
500 different models in 15
categories

Full After Sales Service

Professional customer
service team provides 24/7
customer service

GET A QUOTE

Get in Touch

×